Skip to products

Laboratory Ion-Selective Electrodes

Source-listed laboratory ion-selective electrodes. Ask our team to confirm the selected configuration, technical documentation, availability and quotation. Listed options are not stock commitments.

Confirm the current configuration, availability and applicable documentation with our team before ordering.

Explore the range

37 models

Image available on enquiry.

FC300B sodium combination ion-selective electrode

Manufacturer model
FC300B
Analyte
Sodium (Na+)
Electrode type
Combination ion-selective electrode
Body
Glass; refillable
Reference
Ag/AgCl
Junction
Single ceramic
Fill electrolyte
Ammonium chloride / silver chloride
Sodium range
0.23 to 22,990 mg/L
Connector
BNC

Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.

Enquire about this model

Image available on enquiry.

Silver/Sulfide Combination Ion-Selective Electrode (ISE) – HI4115

Analyte / function
Silver / sulfide
Sensing element
Solid-state silver/silver-sulfide pellet
Body
PEI
Electrode format
Combination ion-selective
Connector
BNC

Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.

Enquire about this model

Image available on enquiry.

Potassium Module for Combination ISE – HI4114-51

Analyte
Potassium
Compatible electrode
HI4114
Sensing element
Valinomycin-containing polymer in PVC

Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.

Enquire about this model

Image available on enquiry.

Potassium Combination Ion-Selective Electrode (ISE) – HI4114

Analyte / function
Potassium
Sensing element
Liquid polymer membrane
Body
PEI
Electrode format
Combination ion-selective
Connector
BNC

Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.

Enquire about this model

Image available on enquiry.

Nitrate Module for Combination ISE (3 pcs) – HI4113-53

Analyte
Nitrate
Compatible electrode
HI4113
Sensing element
Organic nitrate-sensitive polymer in PVC
Pack
3 modules

Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.

Enquire about this model

Image available on enquiry.

Nitrate Combination Ion Selective Electrode (ISE) – HI4113

Analyte / function
Nitrate
Sensing element
Liquid polymer membrane
Body
PEI
Electrode format
Combination ion-selective
Connector
BNC

Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.

Enquire about this model

Image available on enquiry.

Lead/Sulfate Combination Ion-Selective Electrode (ISE) – HI4112

Analyte / function
Lead / sulfate titration indicator
Sensing element
Solid-state lead-sulfide pellet
Body
PEI
Electrode format
Combination ion-selective
Connector
BNC

Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.

Enquire about this model

Image available on enquiry.

Iodide Combination Ion-Selective Electrode (ISE) – HI4111

Analyte / function
Iodide
Sensing element
Solid-state silver-iodide pellet
Body
PEI
Electrode format
Combination ion-selective
Connector
BNC

Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.

Enquire about this model

Image available on enquiry.

Fluoride Module for Combination ISE – HI4110-51

Analyte
Fluoride
Compatible electrode
HI4110
Sensing element
Lanthanum-fluoride crystal

Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.

Enquire about this model

Image available on enquiry.

Fluoride Combination Ion-Selective Electrode (ISE) – HI4110

Analyte / function
Fluoride
Sensing element
Lanthanum-fluoride crystal
Body
PEI / epoxy
Electrode format
Combination ion-selective
Connector
BNC

Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.

Enquire about this model

Image available on enquiry.

Cyanide Combination Ion-Selective Electrode (ISE) – HI4109

Analyte / function
Cyanide
Sensing element
Solid-state silver-halide pellet
Body
PEI
Electrode format
Combination ion-selective
Connector
BNC

Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.

Enquire about this model

Image available on enquiry.

Copper Combination Ion-Selective Electrode (ISE) – HI4108

Analyte / function
Copper
Sensing element
Cupric-sulfide / silver-sulfide pellet
Body
PEI
Electrode format
Combination ion-selective
Connector
BNC

Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.

Enquire about this model

Image available on enquiry.

Chloride Combination Ion-Selective Electrode (ISE) – HI4107

Analyte / function
Chloride
Sensing element
Solid-state silver-chloride pellet
Body
PEI
Electrode format
Combination ion-selective
Connector
BNC

Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.

Enquire about this model

Image available on enquiry.

Carbon Dioxide Combination Ion-Selective Electrode (ISE) – HI4105

Analyte / function
Dissolved carbon dioxide
Sensing element
Gas-permeable PTFE membrane
Body
Delrin
Electrode format
Combination ion-selective
Connector
BNC

Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.

Enquire about this model

Image available on enquiry.

Calcium Module for Combination ISE – HI4104-51

Analyte
Calcium
Compatible electrode
HI4104
Sensing element
Organic calcium-sensitive polymer in PVC

Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.

Enquire about this model

Image available on enquiry.

Calcium Combination Ion-Selective Electrode (ISE) – HI4104

Analyte / function
Calcium
Sensing element
Liquid polymer membrane
Body
PEI
Electrode format
Combination ion-selective
Connector
BNC

Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.

Enquire about this model

Image available on enquiry.

Cadmium Combination Ion-Selective Electrode (ISE) – HI4103

Analyte / function
Cadmium
Sensing element
Cadmium-sulfide / silver-sulfide pellet
Body
PEI
Electrode format
Combination ion-selective
Connector
BNC

Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.

Enquire about this model

Image available on enquiry.

Bromide Combination Ion-Selective Electrode (ISE) – HI4102

Analyte / function
Bromide
Sensing element
Solid-state silver-bromide pellet
Body
PEI
Electrode format
Combination ion-selective
Connector
BNC

Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.

Enquire about this model

Image available on enquiry.

Ammonia Combination Ion-Selective Electrode (ISE) – HI4101

Analyte / function
Ammonia
Sensing element
Gas-permeable PTFE membrane
Body
Delrin
Electrode format
Combination ion-selective
Connector
BNC

Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.

Enquire about this model

Image available on enquiry.

Silver/Sulfide Half-Cell Ion-Selective Electrode (ISE) – HI4015

Analyte
Silver / sulfide
Format
ISE sensing half-cell
Sensing element
Silver / silver-sulfide pellet
Body
Epoxy
Connector
BNC
Reference arrangement
Separate reference half-cell

Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.

Enquire about this model

Image available on enquiry.

Potassium Module for Half-Cell ISE – HI4014-51

Analyte
Potassium
Compatible electrode
HI4014 half-cell
Sensing module
Polymer in PVC matrix

Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.

Enquire about this model

Image available on enquiry.

Potassium Half-Cell Ion-Selective Electrode (ISE) – HI4014

Analyte
Potassium
Format
ISE sensing half-cell
Sensing element
Liquid polymer membrane
Body
Epoxy
Connector
BNC
Reference arrangement
Separate reference half-cell

Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.

Enquire about this model

Image available on enquiry.

Nitrate Module for Half-Cell ISE (3 pcs) – HI4013-53

Analyte
Nitrate
Compatible electrode
HI4013 half-cell
Sensing module
Polymer in PVC matrix
Quantity
3 modules

Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.

Enquire about this model

Image available on enquiry.

Nitrate Half-Cell Ion Selective Electrode (ISE) – HI4013

Analyte
Nitrate
Format
ISE sensing half-cell
Sensing element
Liquid polymer membrane
Body
Epoxy
Connector
BNC
Reference arrangement
Separate reference half-cell

Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.

Enquire about this model

Image available on enquiry.

Lead/Sulfate Half-Cell Ion-Selective Electrode (ISE) – HI4012

Analyte
Lead; sulfate titration indicator
Format
ISE sensing half-cell
Sensing element
Lead-sulfide pellet
Body
Epoxy
Connector
BNC
Reference arrangement
Separate reference half-cell

Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.

Enquire about this model

Image available on enquiry.

Iodide Half-Cell Ion-Selective Electrode (ISE) – HI4011

Analyte
Iodide
Format
ISE sensing half-cell
Sensing element
Silver-iodide pellet
Body
Epoxy
Connector
BNC
Reference arrangement
Separate reference half-cell

Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.

Enquire about this model

Image available on enquiry.

Fluoride Half-Cell Ion-Selective Electrode (ISE) – HI4010

Analyte
Fluoride
Format
ISE sensing half-cell
Sensing element
Lanthanum-fluoride crystal
Body
Epoxy
Connector
BNC
Reference arrangement
Separate reference half-cell

Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.

Enquire about this model

Image available on enquiry.

Cyanide Half-Cell Ion-Selective Electrode (ISE) – HI4009

Analyte
Cyanide
Format
ISE sensing half-cell
Sensing element
Silver-halide pellet
Body
Epoxy
Connector
BNC
Reference arrangement
Separate reference half-cell

Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.

Enquire about this model

Image available on enquiry.

Copper Half-Cell Ion Selective Electrode (ISE) – HI4008

Analyte
Copper
Format
ISE sensing half-cell
Sensing element
Cupric-sulfide / silver-sulfide pellet
Body
Epoxy
Connector
BNC
Reference arrangement
Separate reference half-cell

Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.

Enquire about this model

Image available on enquiry.

Chloride Half-Cell Ion-Selective Electrode (ISE) – HI4007

Analyte
Chloride
Format
ISE sensing half-cell
Sensing element
Silver-chloride pellet
Body
Epoxy
Connector
BNC
Reference arrangement
Separate reference half-cell

Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.

Enquire about this model

Image available on enquiry.

Calcium Module for Half-Cell ISE – HI4004-51

Analyte
Calcium
Compatible electrode
HI4004 half-cell
Sensing module
Polymer in PVC matrix

Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.

Enquire about this model

Image available on enquiry.

Calcium Half-Cell Ion-Selective Electrode (ISE) – HI4004

Analyte
Calcium
Format
ISE sensing half-cell
Sensing element
Liquid polymer membrane
Body
Epoxy
Connector
BNC
Reference arrangement
Separate reference half-cell

Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.

Enquire about this model

Image available on enquiry.

Cadmium Half-Cell Ion-Selective Electrode (ISE) – HI4003

Analyte
Cadmium
Format
ISE sensing half-cell
Sensing element
Cadmium-sulfide / silver-sulfide pellet
Body
Epoxy
Connector
BNC
Reference arrangement
Separate reference half-cell

Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.

Enquire about this model

Image available on enquiry.

Bromide Half-Cell Ion-Selective Electrode (ISE) – HI4002

Analyte
Bromide
Format
ISE sensing half-cell
Sensing element
Silver-bromide pellet
Body
Epoxy
Connector
BNC
Reference arrangement
Separate reference half-cell

Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.

Enquire about this model

Image available on enquiry.

HI7609829-12 nitrate-selective sensor

Analyte
Nitrate-nitrogen in freshwater
Sensing membrane
Polymeric membrane in a PVC head
Reference
Double junction; Ag/AgCl gel-filled reference chamber
Installation
pH sensor socket of the probe
Supplier SKU
HI7609829-12

Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.

Enquire about this model

Image available on enquiry.

HI7609829-11 chloride-selective sensor

Analyte
Free chloride ions in freshwater
Sensing element
Silver chloride pellet
Reference
Double junction; Ag/AgCl gel-filled reference chamber
Installation
pH sensor socket of the probe
Supplier SKU
HI7609829-11

Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.

Enquire about this model

Image available on enquiry.

HI7609829-10 ammonium-selective sensor

Analyte
Free ammonium-nitrogen in freshwater
Sensing membrane
Polymeric membrane in a PVC head
Reference
Double junction; Ag/AgCl gel-filled reference chamber
Installation
pH sensor socket of the probe
Supplier SKU
HI7609829-10

Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.

Enquire about this model

Let’s find the right solution.

Send your preferred model and requirements. Our team can confirm specifications and current supply options.

Enquire on WhatsApp

Enquire with Adamsmed

Your details are not saved on this website. WhatsApp will open with a draft for you to review and send. Please don’t include patient or sensitive health information.