Source-listed laboratory turbidity meters. Ask our team to confirm the selected configuration, technical documentation, availability and quotation. Listed options are not stock commitments.
Confirm the current configuration, availability and applicable documentation with our team before ordering.
Product image available on enquiry.
Explore the range
14 models
Image available on enquiry.
Turbidity (ISO) Portable Meter – HI98713
Meter reference
HI98713
Measurement
Portable water turbidity
Light source
Infrared LED
Detectors
90° scattered and 180° transmitted light
Data connections
USB and RS232
Turbidity range
0.00 to 1000 FNU
Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.
Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.
0.00 to 1000 FNU; 10.0 to 4000 FAU; 0.00 to 4000 NTU ratio; 0.00 to 1000 NTU non-ratio
Storage
Up to 200 measurements
Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.
Portable turbidity and chlorine meter – HI93414 (230V)
Model
HI93414
Source-listed supply option
230V
Turbidity range
0.00 to 1000 NTU
Free and total chlorine range
0.00 to 5.00 mg/L (ppm)
Storage
Up to 200 measurements
Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.
Meter; two cuvettes and caps; four 1.5 V AA batteries; instructions; HI93703-0 and HI93703-10 solutions; cuvette-wiping tissue; carrying case
Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.
Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.
HI93414 turbidity and chlorine meter with 115 V adapter
Model
HI93414
Ordering reference
HI93414-01
Supply configuration
115 V AC adapter option
Turbidity range
0.00 to 1000 NTU
Free and total chlorine range
0.00 to 5.00 mg/L
Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.
Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.
Turbidity, free and total chlorine, cyanuric acid, pH, iodine, bromine and low-range iron
Logging capacity
Up to 25 readings
Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.
Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.
Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.
HI88713 benchtop turbidity meter — HI88713-01, 115 V
Model series
HI88713
Manufacturer ordering reference
HI88713-01
Supply configuration
115 V
Measurement modes
FNU, FAU, NTU ratio and NTU non-ratio
Ranges
0.00 to 1000 FNU; 10.0 to 4000 FAU; 0.00 to 4000 NTU ratio; 0.00 to 1000 NTU non-ratio
Data storage
Up to 200 measurements
Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.
±2% of reading plus 0.02 NTU; ±5% of reading above 1000 NTU
Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.
Confirm the exact configuration, supplied accessories, availability and applicable documentation with our team. Specifications are source-listed; configuration options are not separate stock commitments.